Schneider Electric C60H3P25AC — 2-Pole MCB (DIN Rail)

Schneider Electric C60H3P25AC MCB, C Curve, 25 A, 3P, Multi9

MPNC60H3P25AC
Obsolete

Schneider Electric Multi9 C60H, C60H3P25AC, miniature circuit breaker, 3P, 25 A, C curve, 10 kA at 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60H3P25AC — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P25AC — Electrical
ParameterValue
Rated current [In]25 A at 30 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P25AC — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P25AC — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P25AC — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

The Schneider Electric C60H3P25AC is a 3-pole C60H miniature circuit breaker from the Multi9 range, rated 25 A at 30 °C with a C trip curve (magnetic tripping between 5 and 10 times In). The C curve means it handles moderate inrush without nuisance tripping — typical for mixed resistive and light inductive loads in commercial or light industrial distribution. The thermal-magnetic trip unit gives you both overload protection (thermal bimetal) and short-circuit protection (magnetic solenoid) in one package.

This breaker carries a 10 kA Icu at 440 V AC per IEC 60947-2, and 15 kA Icu at 400–415 V AC. At the common 230–240 V level it jumps to 30 kA Icu. That matters for selectivity studies: you need the upstream device to hold while this one clears, and the 10 kA at 440 V gives you headroom in most 400 V distribution boards.

Physical integration and environment

Dimensions: 81 mm high, 54 mm wide (6 x 9 mm pitches), 73 mm deep. Fixed mounting on 35 mm DIN rail. The toggle gives clear ON/OFF indication and a contact position indicator confirms the state of the moving contacts. Earth-leakage protection is handled by a separate block — this is the plain MCB, not an RCBO.

Frequently asked questions

How do I get pricing and availability for C60H3P25AC?

We source the C60H3P25AC through independent distribution channels. Submit an RFQ and we will confirm current pricing and availability at quote time.

What is the breaking capacity of this MCB at 400 V?

At 400–415 V AC the C60H3P25AC has a 15 kA Icu per IEC 60947-2. The Ics at that voltage is also 15 kA, meaning it remains functional after clearing a fault at that level.

What wire sizes does the C60H3P25AC accept?

The tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible conductors. Strip length is 14 mm, tightening torque 2 N·m.