Skip to main content
Schneider Electric C60H4P16AD

Schneider Electric C60H4P16AD C60H MCB, 4P D-Curve 16 A

MPN C60H4P16AD
Obsolete

Schneider Electric C60H4P16AD, Multi9 C60H series, 4-pole miniature circuit breaker, D-curve, 16 A rated current at 40 °C, thermal-magnetic trip, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P16AD specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H4P16AD is a 4-pole D-curve miniature circuit breaker from Schneider Electric's Multi9 C60H range, rated 16 A at 40 °C. Breaking capacity is multi-tiered: 10 kA Icn per EN 60898 at 230/400 V AC covers standard distribution panels, while the IEC 60947-2 ratings go higher — 30 kA Icu at 230...240 V AC and up to 50 kA Icu at 250 V DC 4P — giving headroom for high-fault industrial switchboards where SCCR coordination matters. The 4-pole form (4 protected poles) suits three-phase plus neutral applications where all conductors need overcurrent protection.

The toggle provides local ON/OFF indication. Ambient operation range is -25 to 60 °C, storage -40 to 70 °C, with tropicalisation class 2 per IEC 60068-1 for humid environments up to 95% RH at 55 °C.

Dual-rated to IEC 60947-2 (industrial) and EN 60898 (household/residential) standards. Suitability for isolation confirmed per IEC 60947-2. Earth-leakage protection requires a separate Vigi block — not integrated.

MPN
C60H4P16AD