Specifications

C60H4P16AD — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P16AD — Electrical
ParameterValue
Rated current [In]16 A at 40 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)DC AC
Network frequency50/60 Hz
C60H4P16AD — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P16AD — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torquePower circuit: 2 N.m upside 2 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P16AD — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P16AD — Approvals
ParameterValue
Standards / complianceIEC 60947-2 EN 60898

Product details

The C60H4P16AD is a 4-pole D-curve miniature circuit breaker from Schneider Electric's Multi9 C60H range, rated 16 A at 40 °C. Breaking capacity is multi-tiered: 10 kA Icn per EN 60898 at 230/400 V AC covers standard distribution panels, while the IEC 60947-2 ratings go higher — 30 kA Icu at 230...240 V AC and up to 50 kA Icu at 250 V DC 4P — giving headroom for high-fault industrial switchboards where SCCR coordination matters. The 4-pole form (4 protected poles) suits three-phase plus neutral applications where all conductors need overcurrent protection.

The toggle provides local ON/OFF indication. Ambient operation range is -25 to 60 °C, storage -40 to 70 °C, with tropicalisation class 2 per IEC 60068-1 for humid environments up to 95% RH at 55 °C.

Dual-rated to IEC 60947-2 (industrial) and EN 60898 (household/residential) standards. Suitability for isolation confirmed per IEC 60947-2. Earth-leakage protection requires a separate Vigi block — not integrated.

Frequently asked questions

Where can I buy C60H4P16AD?

The C60H4P16AD is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What are the key ratings of C60H4P16AD?

Rated 16 A at 40 °C, 4-pole D-curve with magnetic trip at 10-14 x In, breaking capacity up to 50 kA Icu at 250 V DC 4P per IEC 60947-2, and 10 kA Icn at 230/400 V AC per EN 60898.

What standards does the C60H4P16AD comply with?

Compliant with IEC 60947-2 and EN 60898, with suitability for isolation per IEC 60947-2 and limitation class 3.

MPN