Schneider Electric C60H4P40AB

Schneider Electric C60H4P40AB Miniature Circuit Breaker, 40

MPN C60H4P40AB
Obsolete

Schneider Electric Multi9 C60H series, C60H4P40AB, miniature circuit breaker, 4-pole, 40 A, curve B, 10 kA Icn at 230/400 V AC per EN 60898.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P40AB specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H4P40AB is a 40 A, 4-pole miniature circuit breaker from the Schneider Electric Multi9 C60H series. It uses a thermal-magnetic trip unit with a B curve (magnetic tripping between 3 and 5 times In), making it suitable for protecting wiring and general-purpose loads in distribution panels. Rated breaking capacity is 10 kA Icn at 230/400 V AC per EN 60898, with higher Icu values per IEC 60947-2 — up to 30 kA at 230...240 V AC and 40 kA at 125 V DC for the 4-pole configuration.

The B curve (3–5× In) means the magnetic trip responds between 120 A and 200 A — fast enough to clear a hard short but tolerant of modest inrush, which suits resistive loads and general distribution. The 10 kA Icn per EN 60898 is the rated short-circuit capacity for a standard domestic or light commercial panel at 230/400 V; the higher Icu per IEC 60947-2 (e.g., 30 kA at 230...240 V AC) applies when the breaker is used in an industrial context where the prospective fault current is higher. The service breaking capacity Ics is 7.5 kA at 230/400 V per EN 60898 — the level the breaker can clear and still be used afterward.

This is a distribution-grade MCB for final subcircuits in commercial buildings, light industrial panels, and residential distribution boards. The 4-pole configuration (4 protected poles) makes it suitable for three-phase plus neutral circuits. The toggle switch provides local ON/OFF indication, and the contact position indicator confirms isolation status — it is certified for isolation per IEC 60947-2.

MPN