Schneider Electric C60H4P40AB — 2-Pole MCB (DIN Rail)

Schneider Electric C60H4P40AB Miniature Circuit Breaker, 40

MPNC60H4P40AB
Obsolete

Schneider Electric Multi9 C60H series, C60H4P40AB, miniature circuit breaker, 4-pole, 40 A, curve B, 10 kA Icn at 230/400 V AC per EN 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H4P40AB — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P40AB — Electrical
ParameterValue
Rated current [In]40 A at 30 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)DC AC
Network frequency50/60 Hz
C60H4P40AB — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P40AB — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m upside 3.5 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P40AB — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P40AB — Approvals
ParameterValue
Standards / complianceEN 60898 IEC 60947-2

Product details

The C60H4P40AB is a 40 A, 4-pole miniature circuit breaker from the Schneider Electric Multi9 C60H series. It uses a thermal-magnetic trip unit with a B curve (magnetic tripping between 3 and 5 times In), making it suitable for protecting wiring and general-purpose loads in distribution panels. Rated breaking capacity is 10 kA Icn at 230/400 V AC per EN 60898, with higher Icu values per IEC 60947-2 — up to 30 kA at 230...240 V AC and 40 kA at 125 V DC for the 4-pole configuration.

The B curve (3–5× In) means the magnetic trip responds between 120 A and 200 A — fast enough to clear a hard short but tolerant of modest inrush, which suits resistive loads and general distribution. The 10 kA Icn per EN 60898 is the rated short-circuit capacity for a standard domestic or light commercial panel at 230/400 V; the higher Icu per IEC 60947-2 (e.g., 30 kA at 230...240 V AC) applies when the breaker is used in an industrial context where the prospective fault current is higher. The service breaking capacity Ics is 7.5 kA at 230/400 V per EN 60898 — the level the breaker can clear and still be used afterward.

This is a distribution-grade MCB for final subcircuits in commercial buildings, light industrial panels, and residential distribution boards. The 4-pole configuration (4 protected poles) makes it suitable for three-phase plus neutral circuits. The toggle switch provides local ON/OFF indication, and the contact position indicator confirms isolation status — it is certified for isolation per IEC 60947-2.

Frequently asked questions

Where can I buy C60H4P40AB and how do I get a price?

C60H4P40AB is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to confirm current pricing and availability.

What is the breaking capacity of C60H4P40AB?

The rated breaking capacity is 10 kA Icn at 230/400 V AC per EN 60898, with higher Icu values per IEC 60947-2 including 30 kA at 230...240 V AC and 40 kA at 125 V DC for the 4-pole configuration.

What is C60H4P40AB's depth?

The depth is 73 mm.

What standards does C60H4P40AB comply with?

It complies with EN 60898 and IEC 60947-2, and is certified for isolation per IEC 60947-2. It also meets tropicalisation class 2 per IEC 60068-1.