Schneider Electric C63F32M500

C63F32M500 ComPacT NSX 630F Circuit Breaker, 500 A, 40 kA

MPN C63F32M500
Active

Schneider Electric ComPacT NSX 630F, MCCB, 3P, 500 A at 65 °C, 40 kA Icu at 240 V AC, MicroLogic 2.3 M electronic trip unit, motor protection.

$1,057.12 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C63F32M500 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C63F32M500 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The Schneider Electric C63F32M500 is a ComPacT NSX 630F moulded-case circuit breaker (MCCB) with a MicroLogic 2.3 M electronic trip unit, rated 500 A at 65 °C. It is designed for motor protection in three-phase AC networks at 50/60 Hz. That gives selectivity headroom for a downstream feeder without cascading upstream. For a motor-protection application that means the breaker matches the full-load current of a large motor or a group of motors fed through a common bus.

Motor tripping classes 5, 10, and 20 are selectable, letting you match the breaker's overload curve to the motor's thermal withstand. Class 20 is typical for high-inertia loads like fans or centrifuges; class 5 for pumps that start unloaded. The electronic trip unit also provides local signalling: a flashing green LED indicates the breaker is ready to operate; a red LED at 95 % Ith warns of temperature approaching the set point.

IP40 enclosure protection keeps out tools and small debris; IK07 impact resistance handles typical panel-door knocks. Relative humidity range 0...95 % covers non-condensing conditions in unheated electrical rooms.

MPN
C63F32M500