Skip to main content
Schneider Electric C63N31M500

Schneider Electric C63N31M500 ComPacT NSX630N Circuit Breake

MPN C63N31M500
Active

Schneider Electric ComPacT NSX, NSX630N, circuit breaker, 3P, 500 A at 65 °C, MicroLogic 1.3 M electronic trip unit, 50 kA Icu at 415 V AC, EN/IEC 60947-2.

$1,032.37 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C63N31M500 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C63N31M500 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The C63N31M500 is a Schneider Electric ComPacT NSX630N moulded-case circuit breaker in the ComPacT NSX range, sized for motor protection duty with a 500 A electronic trip unit (MicroLogic 1.3 M) rated at 65 °C. The electronic trip gives you adjustable short-time and instantaneous protection curves, which matters when you're coordinating downstream starters or VFDs and need to ride through inrush without nuisance trips.

Breaking capacity across your voltage levels

The Icu (ultimate breaking capacity) varies with system voltage, which is typical for MCCBs. At 240 V AC it's rated 85 kA, at 415 V it's 50 kA, at 440 V it's 42 kA, at 500 V it's 30 kA, at 525 V it's 22 kA, and at 690 V it holds 10 kA. That means in a 480 V panel (common in North American plants) you're looking at roughly 50 kA SCCR headroom if the assembly is listed to UL 60947-4-1. For European 400 V networks, the 50 kA figure covers most transformer-fed buswork.

The breaker measures 255 mm high by 140 mm wide by 110 mm deep, mounts flat on a backplate in either horizontal or vertical orientation. Front connections top and bottom — no rear-access bus required, which simplifies gland-plate layout in a standard enclosure. Six accessory slots on the front for shunt trips, aux contacts, or alarms — enough for a full complement of status feedback to a PLC.

Durability and thermal handling

Mechanical endurance is 15,000 cycles; electrical endurance at full rated current (440 V In) is 4,000 cycles, and at half current it doubles to 8,000 cycles. That's typical for a 500 A frame — plenty for a motor centre where the breaker cycles maybe a few hundred times a year. Power dissipation is 25 W per pole, so 75 W total for the 3-pole unit at full load. That heat needs to be vented or factored into the enclosure's thermal budget; don't stack it tight against other high-dissipation gear without a derating check.

MPN