Schneider Electric ENW24107

Schneider Electric ENW24107 EasyPact NW Circuit Breaker, 320

MPN ENW24107
Active

Schneider Electric, EasyPact NW, circuit breaker, ENW24107, 3200 A at 40 °C, 50 kA Icu at 440 V AC, 3P, drawout, IP40, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24107 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24107 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

What this 3200 A drawout breaker is for

It's a drawout unit — the breaker chassis stays wired to the bus, and the moving portion pulls out for inspection or swap without killing the main bus. That's the whole point of drawout: you isolate the breaker, rack it out, work on it on the bench, and slide a spare back in. Line-down time measured in minutes, not hours.

Breaking capacity — what the ratings actually mean

The ENW24107 carries a 50 kA Icu (ultimate breaking capacity) at 220…440 V AC, and 42 kA at 690 V AC, both per IEC 60947-2. Icu is the maximum fault the breaker can clear once and still be functional afterward — it's the 'one-shot' rating. For repetitive faults (like a motor starting surge that trips), the Ics (service breaking capacity) is the same 50 kA at 440 V, meaning it can clear that fault level repeatedly without needing replacement. The short-time withstand (Icw) is 50 kA for 1 second at 440 V, which matters for selective coordination downstream — this breaker can sit open while a downstream device clears a lower-level fault, then reclose without damage.

Dimensions: 441 mm wide × 439 mm high × 395 mm deep. That's a big breaker — plan for a dedicated compartment in the switchgear lineup, not a DIN-rail mount. It's IP40 rated (finger-safe, not sealed), so indoor switchboard only. Connection is rear-mounted, vertical or horizontal orientation, with a 115 mm pitch without spreader. The control is push-button only; no motor operator or remote trip included as standard.

Designed and tested to IEC 60947-2 for low-voltage switchgear and controlgear. Rated insulation voltage 1000 V AC, operational voltage 690 V AC, impulse withstand 12 kV. Electrical durability: 5000 cycles at 440 V without maintenance, 2500 cycles at 690 V. Mechanical: 20000 cycles with maintenance, 10000 without. Maximum breaking time 25 ms, closing response 70 ms.