Skip to main content
Schneider Electric ENW24110

Schneider Electric ENW24110 EasyPact NW Circuit Breaker, 100

MPN ENW24110
Active

Schneider Electric EasyPact NW, ENW24110, 3P circuit breaker, 1000 A at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24110 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24110 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

Its 50 kA Icu at 220…440 V AC (42 kA at 690 V) means it can safely interrupt fault currents up to that level without upstream cascading — critical for selectivity studies in low-voltage switchgear. It carries IEC 60947-2 certification, which covers the breaking capacity, utilization category B, and the 12 kV impulse withstand voltage (Uimp) that governs clearance and creepage in the panel. The IP40 enclosure keeps tools and fingers out but does not seal against water; mount it in a cabinet if washdown is nearby.

Integration — what fits and what does not

Fixed mounting on a base plate, rear connections with a 115 mm pitch without spreader. The 422 mm width, 352 mm height, and 297 mm depth mean it occupies a full compartment in a typical low-voltage switchboard — plan for a dedicated cubicle. Vertical or horizontal connection orientation is supported, but the rear-entry terminals dictate bus-bar routing behind the panel.

Key electrical ratings at a glance

Rated operational voltage (Ue) is 690 V AC; rated insulation voltage (Ui) is 1000 V AC. Short-time withstand (Icw) is 50 kA for 1 s at 440 V, 42 kA for 1 s at 690 V, and 25 kA for 3 s at 440/690 V, which supports selective coordination with downstream devices. Maximum breaking time is 25 ms; maximum closing response time is 70 ms.

MPN
ENW24110