Skip to main content
Schneider Electric ENW24125

Schneider Electric ENW24125 EasyPact NW Circuit Breaker, 800

MPN ENW24125
Active

Schneider Electric EasyPact NW, ENW24125, 4P circuit breaker, 800 A rated at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24125 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24125 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

ENW24125 — 800 A EasyPact NW Circuit Breaker for Distribution

The ENW24125 is a fixed-mount, 4-pole circuit breaker from the Schneider Electric EasyPact NW range, rated 800 A at 40 °C and designed for distribution applications per IEC 60947-2. Its 50 kA Icu at 440 V AC (42 kA at 690 V) gives you headroom for high-fault panels — the Ics equals the Icu, so the breaker clears a full fault and stays reusable without derating the service rating.

Rated 800 A at 40 °C, this breaker handles a 800 A continuous load in a 40 °C ambient. The Ics is also 50 kA at 440 V, so after a fault at that level the breaker still operates normally, no replacement needed. The 1000 V rated insulation voltage (Ui) and 690 V operational voltage (Ue) let it work in 400 V and 690 V systems common in European and Asian industrial networks. The 4 poles with 4 protected poles (4d) give full overcurrent protection on all phases plus neutral — neutral protection can be set to 0.5× Ir or 1× Ir, or left unprotected (3D configuration).

Where It Goes — Panel Integration Notes

Fixed mounting on a base plate — no DIN rail here. The rear connection accepts vertical or horizontal busbars; connection pitch is 115 mm without a spreader. Neutral sits on the left. Dimensions: 537 mm wide × 352 mm high × 297 mm deep — plan for a 600 mm wide enclosure minimum to allow cable bending radius and access to the push-button controls. Mechanical durability is 20,000 cycles with maintenance or 10,000 without; electrical durability is 6,000 cycles at 440 V and 4,000 at 690 V without maintenance. That fits normal main-breaker duty in a distribution panel — not intended for frequent switching like a contactor.

MPN
ENW24125