Schneider Electric EasyPact NW, ENW24125, 4P circuit breaker, 800 A rated at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24125 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24125 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24125 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24125 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24125 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24125 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24125 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

ENW24125 — 800 A EasyPact NW Circuit Breaker for Distribution

The ENW24125 is a fixed-mount, 4-pole circuit breaker from the Schneider Electric EasyPact NW range, rated 800 A at 40 °C and designed for distribution applications per IEC 60947-2. Its 50 kA Icu at 440 V AC (42 kA at 690 V) gives you headroom for high-fault panels — the Ics equals the Icu, so the breaker clears a full fault and stays reusable without derating the service rating.

Rated 800 A at 40 °C, this breaker handles a 800 A continuous load in a 40 °C ambient. The Ics is also 50 kA at 440 V, so after a fault at that level the breaker still operates normally, no replacement needed. The 1000 V rated insulation voltage (Ui) and 690 V operational voltage (Ue) let it work in 400 V and 690 V systems common in European and Asian industrial networks. The 4 poles with 4 protected poles (4d) give full overcurrent protection on all phases plus neutral — neutral protection can be set to 0.5× Ir or 1× Ir, or left unprotected (3D configuration).

Where It Goes — Panel Integration Notes

Fixed mounting on a base plate — no DIN rail here. The rear connection accepts vertical or horizontal busbars; connection pitch is 115 mm without a spreader. Neutral sits on the left. Dimensions: 537 mm wide × 352 mm high × 297 mm deep — plan for a 600 mm wide enclosure minimum to allow cable bending radius and access to the push-button controls. Mechanical durability is 20,000 cycles with maintenance or 10,000 without; electrical durability is 6,000 cycles at 440 V and 4,000 at 690 V without maintenance. That fits normal main-breaker duty in a distribution panel — not intended for frequent switching like a contactor.

Frequently asked questions

Where can I buy ENW24125 and how do I get a price?

The ENW24125 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing.

What is ENW24125's breaking capacity at 440 V?

The ENW24125 has a 50 kA Icu (and 50 kA Ics) at 220...440 V AC 50/60 Hz per IEC 60947-2.

What standards does ENW24125 comply with?

It complies with IEC 60947-2 for circuit breakers, and the insulation coordination follows IEC 60664-1 with pollution degree 4.

What is the difference between ENW24125 and a standard molded-case breaker?

The ENW24125 is an air circuit breaker (ACB) from the EasyPact NW series, rated 800 A with 50 kA breaking capacity — typically used as a main or feeder breaker in low-voltage switchboards, where molded-case breakers (MCCBs) top out at lower continuous currents and interrupting ratings in the same footprint.

MPN
ENW24125