Schneider Electric ENW24130

Schneider Electric ENW24130 EasyPact NW Circuit Breaker, 250

MPN ENW24130
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24130, 2500 A at 40 °C, 50 kA Icu at 440 V AC, 4P, IP40, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24130 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24130 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24130 is a fixed-mount, 4-pole EasyPact NW circuit breaker rated 2500 A at 40 °C with a breaking capacity of 50 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) matches the Icu at those voltages, so after clearing a fault at rated Ics the breaker remains functional, not just safe; that matters for processes where a fault can't mean a line-down replacement. The 4P 4d protected poles with left-side neutral suit a 4-wire + ground system where the neutral is switched and protected.

Electrical durability at 440 V is 5,000 cycles without maintenance — that's the number to watch for a breaker that sees frequent switching (e.g., capacitor bank or large motor feeder). If your application cycles more than that per year, consider a contactor in series for the switching duty and let the breaker serve as backup protection only.

Fixed mounting on a base plate, rear connection with a pitch of 115 mm without spreader. The 537 mm width, 352 mm height, 297 mm depth define the footprint for panel layout — this is a substantial frame, not a DIN-rail device. Vertical or horizontal connection orientation gives flexibility for busbar routing.

MPN
ENW24130