Skip to main content
Schneider Electric ENW24130 — Air Circuit Breakers

Schneider Electric ENW24130 EasyPact NW Circuit Breaker, 250

MPNENW24130
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24130, 2500 A at 40 °C, 50 kA Icu at 440 V AC, 4P, IP40, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24130 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24130 — Electrical ratings
ParameterValue
Rated current (In)2500 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24130 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24130 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24130 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24130 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24130 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric ENW24130 is a fixed-mount, 4-pole EasyPact NW circuit breaker rated 2500 A at 40 °C with a breaking capacity of 50 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) matches the Icu at those voltages, so after clearing a fault at rated Ics the breaker remains functional, not just safe; that matters for processes where a fault can't mean a line-down replacement. The 4P 4d protected poles with left-side neutral suit a 4-wire + ground system where the neutral is switched and protected.

Electrical durability at 440 V is 5,000 cycles without maintenance — that's the number to watch for a breaker that sees frequent switching (e.g., capacitor bank or large motor feeder). If your application cycles more than that per year, consider a contactor in series for the switching duty and let the breaker serve as backup protection only.

Fixed mounting on a base plate, rear connection with a pitch of 115 mm without spreader. The 537 mm width, 352 mm height, 297 mm depth define the footprint for panel layout — this is a substantial frame, not a DIN-rail device. Vertical or horizontal connection orientation gives flexibility for busbar routing.

Frequently asked questions

Where can I buy ENW24130 and how do I get a price?

The ENW24130 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest alternative to ENW24130 in the EasyPact NW family?

Within the EasyPact NW range, the closest sibling is the ENW24130 itself — the ENW25N device short name identifies the 2500 A frame. A lower-current variant (e.g., 2000 A) or higher (3200 A) would require a different frame size and different busbar connections; there is no pin-compatible drop-in substitute at a different rating.

What compliance documentation does Schneider provide for ENW24130?

The breaker is designed to IEC 60947-2 and carries an IP40 protection rating. Suitability for isolation is confirmed per IEC 60947-2. Standard Schneider documentation includes a declaration of conformity to the Low Voltage Directive; specific RoHS/REACH declarations are available from Schneider's product documentation portal.

MPN
ENW24130