Schneider Electric ENW24131

Schneider Electric ENW24131 EasyPact NW Circuit Breaker, 320

MPN ENW24131
Active

Schneider Electric EasyPact NW, ENW24131, air circuit breaker, 3200 A, 4P, 50 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24131 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24131 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

3200 A air circuit breaker for distribution

The Schneider Electric ENW24131 is a 4-pole air circuit breaker from the EasyPact NW range, rated 3200 A at 40 °C and built for distribution duty per IEC 60947-2. The 42 kA Icu at 690 V AC covers the higher-voltage end of industrial networks. Both the ultimate (Icu) and service (Ics) breaking capacities are the same figure at each voltage — 50 kA Ics at 440 V, 42 kA Ics at 690 V — so the breaker clears its full rated fault without derating for repetitive duty.

The IP40 enclosure keeps tools and fingers out but is not washdown-rated; mount it in a cabinet if the environment is wet. Electrical durability at 440 V is 5,000 cycles without maintenance — enough for a main breaker that operates infrequently, not a switching device cycling every minute. The 25 ms maximum breaking time means the arc is quenched and the fault cleared in under three line cycles at 50 Hz.

Fixed-mount design on a base plate, rear-connected. The 537 mm width, 352 mm height, and 297 mm depth define the footprint for panel layout — account for the 115 mm connection pitch without spreader when positioning busbars. Neutral is on the left. The push-button control interface means no motor operator is built in; remote closing requires an optional add-on.

MPN
ENW24131