Skip to main content
Schneider Electric ENW24139

Schneider Electric ENW24139 EasyPact NW Circuit Breaker, 320

MPN ENW24139
Active

Schneider Electric EasyPact NW, ENW24139, 3-pole drawout circuit breaker, 3200 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24139 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24139 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

That 3200 A continuous rating means it's sized for the main incoming feeder in a large industrial or utility substation — think a 2 MW transformer secondary at 400 V. The breaking capacity is 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) matches — 65 kA at 440 V, 50 kA at 690 V — meaning after a fault at those levels the breaker is still usable, not a one-shot device. Category B utilization means it's designed for selective coordination downstream, with a deliberate short-time delay so a feeder breaker trips before this main. Insulation voltage is 1000 V AC, impulse withstand 12 kV — that's the margin for transient overvoltages on a 690 V system. IP40 enclosure protection keeps tools and fingers out but isn't washdown-rated — mount it inside a switchgear cubicle, not outdoors.

Designed and tested to IEC 60947-2 — the international standard for low-voltage circuit breakers. Pollution degree 4 per IEC 60664-1 covers heavy industrial environments. The manufacturer provides a declaration of conformity, IEC test certificates, and a technical manual covering installation, maintenance, and coordination curves. No RoHS or REACH statements are in the evidence, but Schneider typically includes those in the product documentation pack.

MPN