Schneider Electric ENW24146 EasyPact NW Circuit Breaker, 250

MPN ENW24146
Active

Schneider Electric EasyPact NW, ENW24146, 3-pole fixed circuit breaker, 2500 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24146 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24146 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The 12 kV impulse withstand (Uimp) confirms it handles transient overvoltages common in industrial networks.

Fixed mounting on a base plate, rear connections, and a 115 mm connection pitch without spreader. The 422 mm width, 352 mm height, and 297 mm depth define the panel cutout and clearance needed — factor in the 115 mm pitch when laying out bus bars. IP40 protection means it's indoor-rated, not for washdown; keep it in a clean, dry enclosure.

The ENW24146 is listed as current production, so it's still a standard catalog item from Schneider. No obsolescence notice or last-time-buy on record.

Mechanical durability: 20,000 cycles with maintenance, 10,000 without. Electrical durability: 5,000 cycles at 440 V without maintenance (Category B), 2,500 cycles at 690 V. That's typical for a high-current air breaker — not for frequent switching, but fine for infrequent load-break or fault-interrupt duty. Maximum breaking time is 25 ms, closing response 70 ms, so it coordinates with downstream protective devices on a time-current curve.