Schneider Electric ENW24146 — Air Circuit Breakers

Schneider Electric ENW24146 EasyPact NW Circuit Breaker, 250

MPNENW24146
Active

Schneider Electric EasyPact NW, ENW24146, 3-pole fixed circuit breaker, 2500 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24146 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24146 — Electrical ratings
ParameterValue
Rated current (In)2500 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24146 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24146 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24146 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24146 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24146 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The 12 kV impulse withstand (Uimp) confirms it handles transient overvoltages common in industrial networks.

Fixed mounting on a base plate, rear connections, and a 115 mm connection pitch without spreader. The 422 mm width, 352 mm height, and 297 mm depth define the panel cutout and clearance needed — factor in the 115 mm pitch when laying out bus bars. IP40 protection means it's indoor-rated, not for washdown; keep it in a clean, dry enclosure.

The ENW24146 is listed as current production, so it's still a standard catalog item from Schneider. No obsolescence notice or last-time-buy on record.

Mechanical durability: 20,000 cycles with maintenance, 10,000 without. Electrical durability: 5,000 cycles at 440 V without maintenance (Category B), 2,500 cycles at 690 V. That's typical for a high-current air breaker — not for frequent switching, but fine for infrequent load-break or fault-interrupt duty. Maximum breaking time is 25 ms, closing response 70 ms, so it coordinates with downstream protective devices on a time-current curve.

Frequently asked questions

What are the key ratings for ENW24146?

Rated current 2500 A at 40 °C, breaking capacity 66 kA Icu at 440 V AC, rated operational voltage 690 V AC, and rated insulation voltage 1000 V AC. It complies with IEC 60947-2.

What is the depth of ENW24146?

The depth is 297 mm. Width is 422 mm, height is 352 mm.