Skip to main content
Schneider Electric ENW24149

Schneider Electric ENW24149 EasyPact NW Circuit Breaker, 800

MPN ENW24149
Active

Schneider Electric EasyPact NW air circuit breaker, ENW24149, 800 A, 66 kA Icu at 440 V AC, 4P drawout, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24149 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24149 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24149 is a Schneider Electric EasyPact NW air circuit breaker rated 800 A at 40 °C, built for distribution duty in AC networks at 50/60 Hz. The 66 kA Icu at 220…440 V AC (IEC 60947-2) means it can safely interrupt fault currents up to that level without failing — critical for high-fault-capacity switchboards where upstream coordination depends on the breaker clearing a short circuit within 25 ms maximum breaking time. The 65 kA Ics (service breaking capacity) at the same voltage tells you it can reclose after a fault without immediate maintenance, which matters for continuous-process lines where a single fault shouldn't force a shutdown for inspection. Rated insulation voltage is 1000 V AC, and operational voltage goes to 690 V AC. The 4-pole design (4 protected poles) with neutral on the left supports both 3D and 4D configurations; neutral protection can be set to 0.5 x Ir or 1 x Ir, or left unprotected.

Drawout mounting on a rail with rear horizontal or vertical connections — the breaker chassis slides into a fixed cradle, so you can rack it out for maintenance or replacement without disturbing the bus bars. Dimensions: 556 mm wide, 439 mm high, 395 mm deep. Connection pitch is 115 mm without a spreader. IP40 enclosure protection keeps tools and fingers out but isn't rated for washdown; install in a clean, dry switchgear cubicle.

MPN
ENW24149