Skip to main content
Schneider Electric ENW24149 — Air Circuit Breakers

Schneider Electric ENW24149 EasyPact NW Circuit Breaker, 800

MPNENW24149
Active

Schneider Electric EasyPact NW air circuit breaker, ENW24149, 800 A, 66 kA Icu at 440 V AC, 4P drawout, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24149 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24149 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24149 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24149 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24149 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width556 mm
Height439 mm
Depth395 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24149 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24149 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24149 is a Schneider Electric EasyPact NW air circuit breaker rated 800 A at 40 °C, built for distribution duty in AC networks at 50/60 Hz. The 66 kA Icu at 220…440 V AC (IEC 60947-2) means it can safely interrupt fault currents up to that level without failing — critical for high-fault-capacity switchboards where upstream coordination depends on the breaker clearing a short circuit within 25 ms maximum breaking time. The 65 kA Ics (service breaking capacity) at the same voltage tells you it can reclose after a fault without immediate maintenance, which matters for continuous-process lines where a single fault shouldn't force a shutdown for inspection. Rated insulation voltage is 1000 V AC, and operational voltage goes to 690 V AC. The 4-pole design (4 protected poles) with neutral on the left supports both 3D and 4D configurations; neutral protection can be set to 0.5 x Ir or 1 x Ir, or left unprotected.

Drawout mounting on a rail with rear horizontal or vertical connections — the breaker chassis slides into a fixed cradle, so you can rack it out for maintenance or replacement without disturbing the bus bars. Dimensions: 556 mm wide, 439 mm high, 395 mm deep. Connection pitch is 115 mm without a spreader. IP40 enclosure protection keeps tools and fingers out but isn't rated for washdown; install in a clean, dry switchgear cubicle.

Frequently asked questions

What is ENW24149's listed depth (395 mm) on this component line?

The ENW24149 has a depth of 395 mm, as listed in the specifications.

What is ENW24149's listed range (EasyPact) on this component line?

The ENW24149 belongs to the Schneider Electric EasyPact range, specifically the EasyPact NW series of air circuit breakers.

What compliance documentation does this brand provide for ENW24149 (RoHS, REACH, UL, IEC)?

The ENW24149 is designed to meet IEC 60947-2 and carries isolation suitability per that standard. RoHS and REACH compliance are standard for Schneider Electric EasyPact products, but specific declarations should be confirmed at quote time.

MPN
ENW24149