Schneider Electric ENW24152

Schneider Electric ENW24152 EasyPact NW Circuit Breaker, 160

MPN ENW24152
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24152, 1600 A at 40 °C, 66 kA Icu at 440 V AC, 4P, drawout, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24152 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24152 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24152 is a 4-pole EasyPact NW drawout circuit breaker rated 1600 A at 40 °C, built to IEC 60947-2 for distribution duty. The drawout cradle lets you rack the breaker out for safe maintenance or swap without disturbing the bus connections, which cuts downtime on a line-down event.

Breaking capacity and duty

The H breaking-capacity code means this unit is the high-interrupting version of the EasyPact NW frame. At 440 V the Icu is 66 kA; the Ics (service breaking capacity) is 65 kA — 98% of Icu, so it can reclose after a fault at nearly full rating without derating the next interruption. At 690 V both Icu and Ics drop to 50 kA, still adequate for most 690 V distribution. Category B utilization means the breaker is designed for selectivity with downstream devices: it withstands a let-through current without tripping, so only the faulted branch opens.

Drawout mounting on a rail support with rear connection. The 115 mm connection pitch without spreader sets the bus-bar drilling pattern. Neutral position is left.

Durability and service life

Electrical durability at 440 V is 6,000 cycles without maintenance, dropping to 4,000 at 690 V. Maximum breaking time is 25 ms; maximum closing response time is 70 ms. These numbers govern the maintenance interval: plan an inspection after 10,000 mechanical operations or 4,000 full-load breaks at 690 V, whichever comes first.

MPN