Schneider Electric ENW24238 EasyPact NW Circuit Breaker, 100

MPN ENW24238
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24238, 1000 A at 40 °C, 50 kA Icu at 440 V AC, 4P, IP40, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24238 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24238 is a 4-pole EasyPact NW air circuit breaker rated 1000 A at 40 °C — that's the continuous current it carries without derating in a 40 °C ambient. At 690 V the Icu drops to 42 kA, which still covers most industrial distribution secondaries. The Ics (service breaking capacity) matches the Icu at both voltage levels — so you get full rated breaking capacity on reclose, not a derated service rating. That matters for selectivity studies where you need the downstream breaker to clear before the upstream trips.

Mounting and integration — fixed base plate, rear connections

Fixed mounting on a base plate, not a DIN rail — this is a drawout-style frame that bolts into a switchboard cubicle. Rear connection terminals with a 115 mm pitch without spreader, horizontal or vertical orientation. The footprint is 537 mm wide by 352 mm high by 297 mm deep, so plan the gland plate and busbar clearance accordingly. Pollution degree 4 per IEC 60664-1 means it's rated for continuous conductive contamination (dust, condensation) — typical in cement plants, steel mills, or outdoor substations where a standard IP2X breaker wouldn't hold up. IP40 enclosure keeps tools and fingers out but isn't washdown-rated.

Standards and approvals — IEC 60947-2, isolation suitability

Built and tested to IEC 60947-2 for low-voltage switchgear and controlgear. Rated insulation voltage 1000 V AC, impulse withstand 12 kV. Mechanical durability 20,000 cycles with maintenance, 10,000 without. Electrical durability at 440 V is 6,000 cycles Category B without maintenance.