Skip to main content
Schneider Electric ENW24246

Schneider Electric ENW24246 EasyPact NW Circuit Breaker, 100

MPN ENW24246
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24246, 4-pole drawout, 1000 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24246 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24246 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24246 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 1000 A at 40 °C. For the sourcing buyer: this is the main line-side breaker for a 1000 A bus, not a feeder or branch device. Breaking capacity is 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The Icu is the ultimate short-circuit capacity the breaker can interrupt once and still be functional afterward. Drawout mounting means the breaker chassis stays wired to the bus; the moving portion pulls out for inspection or swap without disturbing the cable connections. Rear connection and vertical/horizontal orientation are both supported — check your switchgear layout for the connection pitch of 115 mm without spreader.

Pollution degree 4 per IEC 60664-1 is the highest industrial severity: conductive dust or heavy condensation expected. The breaker is designed for that environment, but the enclosure around it must keep the IP40 rating intact. Ambient operating range is -5 to 60 °C; storage from -40 to 85 °C without control unit, -25 to 85 °C with control unit. Electrical durability at 440 V is 6,000 cycles without maintenance — enough for a main breaker that operates infrequently.

MPN
ENW24246