Schneider Electric ENW24246 — Air Circuit Breakers

Schneider Electric ENW24246 EasyPact NW Circuit Breaker, 100

MPNENW24246
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24246, 4-pole drawout, 1000 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24246 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24246 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24246 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24246 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24246 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width556 mm
Height439 mm
Depth395 mm
Neutral pole positionRight
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24246 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24246 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24246 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 1000 A at 40 °C. For the sourcing buyer: this is the main line-side breaker for a 1000 A bus, not a feeder or branch device. Breaking capacity is 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The Icu is the ultimate short-circuit capacity the breaker can interrupt once and still be functional afterward. Drawout mounting means the breaker chassis stays wired to the bus; the moving portion pulls out for inspection or swap without disturbing the cable connections. Rear connection and vertical/horizontal orientation are both supported — check your switchgear layout for the connection pitch of 115 mm without spreader.

Pollution degree 4 per IEC 60664-1 is the highest industrial severity: conductive dust or heavy condensation expected. The breaker is designed for that environment, but the enclosure around it must keep the IP40 rating intact. Ambient operating range is -5 to 60 °C; storage from -40 to 85 °C without control unit, -25 to 85 °C with control unit. Electrical durability at 440 V is 6,000 cycles without maintenance — enough for a main breaker that operates infrequently.

Frequently asked questions

What is ENW24246's breaking capacity at 440 V?

The ENW24246 has a rated ultimate breaking capacity (Icu) of 66 kA at 220...440 V AC and a service breaking capacity (Ics) of 65 kA at the same voltage range, both per IEC 60947-2.

What compliance documentation does ENW24246 carry?

The ENW24246 is certified to IEC 60947-2 and carries suitability for isolation per that standard. Pollution degree 4 per IEC 60664-1 is specified. For RoHS, REACH, or UL documentation, request the manufacturer's compliance declarations with your RFQ.