Specifications

ENW24249 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24249 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24249 is a 4-pole EasyPact NW drawout circuit breaker rated 2000 A at 40 °C. That 2000 A continuous current makes it a main or heavy feeder breaker for large distribution switchboards — think plant incoming supply or a big motor control center bus. At 690 V the Icu drops to 50 kA, so if your system runs at 690 V, coordination studies need that lower figure. That's a Category B utilization characteristic: the breaker is intended for selective coordination with downstream devices, not just cable protection.

The ENW24249 is listed as current production within the EasyPact NW range. That means it's still a standard catalog item, not a phase-out or last-time-buy part.

Integration notes

Drawout mounting on a rail means the breaker slides into a cradle — you can rack it out for maintenance or replacement without disconnecting the main power cables. The rear connection position with vertical or horizontal orientation suits rear-accessible switchgear lineups. Physical footprint: 556 mm wide, 439 mm high, 395 mm deep. The 115 mm connection pitch without spreader matters for busbar drilling patterns.

Designed and tested to IEC 60947-2 for low-voltage switchgear and controlgear. Suitability for isolation is confirmed — important for a visible-break isolation point in a maintenance lockout procedure. The electrical durability figures give 6000 cycles at 440 V and 4000 cycles at 690 V without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. These numbers drive the inspection interval in a preventive maintenance schedule.