Active

Schneider Electric EasyPact NW, circuit breaker, ENW24249, 4P, 2000 A at 40 °C, 66 kA Icu at 440 V AC, drawout mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24249 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24249 — Electrical ratings
ParameterValue
Rated current (In)2000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24249 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24249 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24249 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width556 mm
Height439 mm
Depth395 mm
Neutral pole positionRight
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24249 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24249 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24249 is a 4-pole EasyPact NW drawout circuit breaker rated 2000 A at 40 °C. That 2000 A continuous current makes it a main or heavy feeder breaker for large distribution switchboards — think plant incoming supply or a big motor control center bus. At 690 V the Icu drops to 50 kA, so if your system runs at 690 V, coordination studies need that lower figure. That's a Category B utilization characteristic: the breaker is intended for selective coordination with downstream devices, not just cable protection.

The ENW24249 is listed as current production within the EasyPact NW range. That means it's still a standard catalog item, not a phase-out or last-time-buy part.

Integration notes

Drawout mounting on a rail means the breaker slides into a cradle — you can rack it out for maintenance or replacement without disconnecting the main power cables. The rear connection position with vertical or horizontal orientation suits rear-accessible switchgear lineups. Physical footprint: 556 mm wide, 439 mm high, 395 mm deep. The 115 mm connection pitch without spreader matters for busbar drilling patterns.

Designed and tested to IEC 60947-2 for low-voltage switchgear and controlgear. Suitability for isolation is confirmed — important for a visible-break isolation point in a maintenance lockout procedure. The electrical durability figures give 6000 cycles at 440 V and 4000 cycles at 690 V without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. These numbers drive the inspection interval in a preventive maintenance schedule.

Frequently asked questions

What is the breaking capacity of ENW24249?

The ENW24249 has a rated breaking capacity (Icu) of 66 kA at 220…440 V AC and 50 kA at 690 V AC, both per IEC 60947-2. The service breaking capacity (Ics) is 65 kA at 440 V and 50 kA at 690 V.

How do I get pricing and availability for ENW24249?

The ENW24249 is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at the time of quote — submit an RFQ for a firm price and lead time.

What is the closest alternative to ENW24249 in the EasyPact NW family?

The ENW24249 is a specific order code within the EasyPact NW range. Other order codes in the same family differ by rated current, number of poles, or breaking capacity code. There is no single pin-compatible drop-in; the correct substitute depends on the required current rating and interrupting capacity for your application.