Skip to main content
Schneider Electric EVS08H3NW5A

Schneider Electric EVS08H3NW5A EasyPact EVS Circuit Breaker,

MPN EVS08H3NW5A
Active

Schneider Electric EasyPact EVS, EVS08H3NW5A, drawout circuit breaker, 800 A, 65 kA Icu at 440 V AC, 3P, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS08H3NW5A key specifications
ParameterValue
Control typeElectrically operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS08H3NW5A additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The EVS08H3NW5A is a Schneider Electric EasyPact EVS drawout circuit breaker rated 800 A at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The electronic EVS Trip System5A unit provides overload (long-time), instantaneous short-circuit, and short-time short-circuit protection, with a 20-minute thermal memory before and after tripping so it remembers prior heating events and doesn't reset too aggressively. It is a 3-pole (3P 3d) device with rear vertical or horizontal connection, drawout mounting on a rail or base plate, and a 115 mm connection pitch without spreader. The drawout design means the breaker can be racked out for safe maintenance without disconnecting power wiring — standard for switchgear where uptime and isolation matter. IP40 protection suits indoor panel environments; pollution degree 4 per IEC 60664-1 means it tolerates conductive dust or heavy condensation, so it's suited for industrial distribution boards in pulp/paper, cement, or similar dirty atmospheres.

Integration notes for panel builders

Physical footprint: 441 mm wide, 439 mm high, 395 mm deep. Drawout chassis requires rear access for the power connections (vertical or horizontal orientation). The 115 mm pole pitch without spreader matches standard bus-bar spacing in LV switchgear. Electrically operated via the control circuit, with a digital display on the trip unit for fault indication (overload, short-circuit, internal fault). Contact position indicator gives visual confirmation of open/closed state without opening the door. Rated for category B utilization — 5000 electrical cycles at 440/690 V without maintenance per IEC 60947-2, and 20000 mechanical cycles with maintenance. The 25 ms maximum breaking time means fast fault clearance, which limits let-through energy on downstream components.

MPN