EVS08H3NW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS08H3NW5A — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS08H3NW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS08H3NW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS08H3NW5A — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS08H3NW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS08H3NW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The EVS08H3NW5A is a Schneider Electric EasyPact EVS drawout circuit breaker rated 800 A at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The electronic EVS Trip System5A unit provides overload (long-time), instantaneous short-circuit, and short-time short-circuit protection, with a 20-minute thermal memory before and after tripping so it remembers prior heating events and doesn't reset too aggressively. It is a 3-pole (3P 3d) device with rear vertical or horizontal connection, drawout mounting on a rail or base plate, and a 115 mm connection pitch without spreader. The drawout design means the breaker can be racked out for safe maintenance without disconnecting power wiring — standard for switchgear where uptime and isolation matter. IP40 protection suits indoor panel environments; pollution degree 4 per IEC 60664-1 means it tolerates conductive dust or heavy condensation, so it's suited for industrial distribution boards in pulp/paper, cement, or similar dirty atmospheres.

Integration notes for panel builders

Physical footprint: 441 mm wide, 439 mm high, 395 mm deep. Drawout chassis requires rear access for the power connections (vertical or horizontal orientation). The 115 mm pole pitch without spreader matches standard bus-bar spacing in LV switchgear. Electrically operated via the control circuit, with a digital display on the trip unit for fault indication (overload, short-circuit, internal fault). Contact position indicator gives visual confirmation of open/closed state without opening the door. Rated for category B utilization — 5000 electrical cycles at 440/690 V without maintenance per IEC 60947-2, and 20000 mechanical cycles with maintenance. The 25 ms maximum breaking time means fast fault clearance, which limits let-through energy on downstream components.

Frequently asked questions

Where can I buy EVS08H3NW5A and get a price?

The EVS08H3NW5A is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of EVS08H3NW5A?

The EVS08H3NW5A has a 65 kA Icu breaking capacity at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2.

What compliance documentation does Schneider provide for EVS08H3NW5A?

The EVS08H3NW5A is designed to IEC 60947-2 standards and carries pollution degree 4 per IEC 60664-1. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration at quote time.

MPN
EVS08H3NW5A