Skip to main content
Schneider Electric EVS10H3MF60

Schneider Electric EVS10H3MF60 EasyPact EVS Circuit Breaker,

MPN EVS10H3MF60
Active

Schneider Electric EasyPact EVS, molded-case circuit breaker, EVS10H3MF60, 3-pole, 1000 A, 65 kA Icu at 440 V AC, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS10H3MF60 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS10H3MF60 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What this breaker delivers

The Schneider Electric EVS10H3MF60 is a 3-pole molded-case circuit breaker from the EasyPact EVS range, rated 1000 A at 40 °C and carrying a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. At 690 V the Icu drops to 50 kA — still enough for most 690 V distribution boards, but verify your fault level if you are on a high-capacity 690 V bus. The electronic trip unit — EVS Trip System6.0 — provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection.

Fixed-mount design with rear connection. Occupies 422 mm width × 352 mm height × 297 mm depth — factor that into your enclosure depth budget, especially if you are back-paneling with a gland plate behind it. Mounts on a rail or base plate. Connection pitch is 115 mm without a spreader; vertical or horizontal orientation is allowed. IP40 front face keeps out tools and finger probes, but the enclosure must handle the rest — this is not a washdown-rated device.

Durability and fault indication

Mechanical endurance: 20,000 cycles with maintenance, 10,000 without. Electrical endurance in Category B (distribution duty) is 5,000 cycles at 440/690 V without maintenance — this is a switchboard main or heavy feeder breaker, not a daily motor-switching device. Fault indication covers internal fault, overload, short-circuit, and earth fault — the trip unit flags the cause, so a returning technician sees what cleared the breaker without needing a separate event logger. Pollution degree 4 per IEC 60664-1 means it tolerates conductive dust and heavy condensation — suitable for industrial environments where a standard IP20 breaker might track across terminals.

MPN
EVS10H3MF60