Skip to main content
Schneider Electric EVS12H3NW5A

Schneider Electric EVS12H3NW5A EasyPact EVS Circuit Breaker,

MPN EVS12H3NW5A
Active

Schneider Electric EasyPact EVS drawout circuit breaker, 3-pole, 1250 A, 65 kA Icu at 440 V AC, electronic trip unit, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS12H3NW5A key specifications
ParameterValue
Control typeElectrically operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS12H3NW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS12H3NW5A is a 3-pole drawout circuit breaker from the EasyPact EVS family, rated 1250 A at 40 °C and built to IEC 60947-2. At 690 V AC the breaking capacity drops to 50 kA Icu, still enough for most 690 V distribution applications.

Drawout form factor and panel integration

Drawout mounting means the breaker slides into a cradle on a rail or base plate — you can rack it out for maintenance or replacement without disturbing the bus connections. The rear connection terminals accept vertical or horizontal bus bar orientation, with a 115 mm connection pitch without spreader. That pitch matches standard switchgear bus spacing; if you need to adapt to a different pitch, a spreader kit is available.

Durability and fault response

Electrical durability is 5,000 cycles at 440/690 V AC without maintenance — that is the number to watch for frequent switching applications; if your process cycles the breaker daily, the electrical endurance may govern the replacement interval. Maximum breaking time is 25 ms, fast enough to limit let-through energy and coordinate with downstream breakers. The digital display shows fault type — internal fault, overload, or short-circuit — which speeds troubleshooting on a distribution board.

MPN