Schneider Electric EVS12H3NW5A — Air Circuit Breakers

Schneider Electric EVS12H3NW5A EasyPact EVS Circuit Breaker,

MPNEVS12H3NW5A
Active

Schneider Electric EasyPact EVS drawout circuit breaker, 3-pole, 1250 A, 65 kA Icu at 440 V AC, electronic trip unit, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS12H3NW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS12H3NW5A — Electrical ratings
ParameterValue
Rated current (In)1250 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS12H3NW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS12H3NW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS12H3NW5A — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS12H3NW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS12H3NW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS12H3NW5A is a 3-pole drawout circuit breaker from the EasyPact EVS family, rated 1250 A at 40 °C and built to IEC 60947-2. At 690 V AC the breaking capacity drops to 50 kA Icu, still enough for most 690 V distribution applications.

Drawout form factor and panel integration

Drawout mounting means the breaker slides into a cradle on a rail or base plate — you can rack it out for maintenance or replacement without disturbing the bus connections. The rear connection terminals accept vertical or horizontal bus bar orientation, with a 115 mm connection pitch without spreader. That pitch matches standard switchgear bus spacing; if you need to adapt to a different pitch, a spreader kit is available.

Durability and fault response

Electrical durability is 5,000 cycles at 440/690 V AC without maintenance — that is the number to watch for frequent switching applications; if your process cycles the breaker daily, the electrical endurance may govern the replacement interval. Maximum breaking time is 25 ms, fast enough to limit let-through energy and coordinate with downstream breakers. The digital display shows fault type — internal fault, overload, or short-circuit — which speeds troubleshooting on a distribution board.

Frequently asked questions

How do I get current pricing and availability for EVS12H3NW5A?

The EVS12H3NW5A is sourced to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time.

What is EVS12H3NW5A's breaking capacity at 440 V AC?

The EVS12H3NW5A has a breaking capacity of 65 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2.

What protection functions does the EVS Trip System5A provide?

The EVS Trip System5A provides overload protection (long time), instantaneous short-circuit protection, and short time short-circuit protection.

What compliance documentation does this brand provide for EVS12H3NW5A?

The EVS12H3NW5A is certified to IEC 60947-2 and is suitable for isolation per that standard; compliance documentation (declaration of conformity, test reports) is available from Schneider Electric.