Schneider Electric EVS16H3NW5A

Schneider Electric EVS16H3NW5A EasyPact EVS Circuit Breaker,

MPN EVS16H3NW5A
Active

Schneider Electric EasyPact EVS, EVS16H3NW5A, 3-pole drawout circuit breaker, 1600 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System5A, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS16H3NW5A key specifications
ParameterValue
Control typeElectrically operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS16H3NW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS16H3NW5A is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 1600 A at 40 °C and built to IEC 60947-2. That 1600 A trip unit rating means it handles full-load current for large distribution feeders — think main switchboards or heavy industrial loads. The electronic EVS Trip System5A gives you overload (long-time), instantaneous short-circuit, and short-time short-circuit protection, plus a digital display for reading fault cause and load current right on the front.

The H breaking capacity code delivers 65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. For a 1600 A frame, that's a high-interrupt rating suited to low-voltage utility transformers in the 2–3 MVA range where available fault current runs high. Maximum breaking time is 25 ms, so it clears fast enough to coordinate with downstream molded-case breakers.

Drawout mounting means the breaker slides into a cradle on a rail or base plate — no hard wiring of the main power connections; the rear connection points engage with stationary disconnects. The 441 mm width, 439 mm height, and 395 mm depth give you the cutout and clearance dimensions for the switchgear lineup. Connection pitch is 115 mm without spreader. IP40 keeps tools and fingers out but isn't sealed against water ingress.

Category B utilization means the breaker is intended for distribution, not direct motor starting — it's the main or feeder breaker, not a combination starter. Electrical durability is 5000 cycles at 440/690 V without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without.

MPN
EVS16H3NW5A