Schneider Electric EasyPact EVS, EVS16H3NW5A, 3-pole drawout circuit breaker, 1600 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System5A, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS16H3NW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS16H3NW5A — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS16H3NW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS16H3NW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS16H3NW5A — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS16H3NW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS16H3NW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS16H3NW5A is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 1600 A at 40 °C and built to IEC 60947-2. That 1600 A trip unit rating means it handles full-load current for large distribution feeders — think main switchboards or heavy industrial loads. The electronic EVS Trip System5A gives you overload (long-time), instantaneous short-circuit, and short-time short-circuit protection, plus a digital display for reading fault cause and load current right on the front.

The H breaking capacity code delivers 65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. For a 1600 A frame, that's a high-interrupt rating suited to low-voltage utility transformers in the 2–3 MVA range where available fault current runs high. Maximum breaking time is 25 ms, so it clears fast enough to coordinate with downstream molded-case breakers.

Drawout mounting means the breaker slides into a cradle on a rail or base plate — no hard wiring of the main power connections; the rear connection points engage with stationary disconnects. The 441 mm width, 439 mm height, and 395 mm depth give you the cutout and clearance dimensions for the switchgear lineup. Connection pitch is 115 mm without spreader. IP40 keeps tools and fingers out but isn't sealed against water ingress.

Category B utilization means the breaker is intended for distribution, not direct motor starting — it's the main or feeder breaker, not a combination starter. Electrical durability is 5000 cycles at 440/690 V without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without.

Frequently asked questions

How do I get current pricing and availability for EVS16H3NW5A?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is the closest alternative to EVS16H3NW5A in the EasyPact EVS family?

Within the EasyPact EVS range, the closest sibling would share the same 1600 A frame and EVS Trip System5A but differ in breaking capacity code (H vs S vs L) or poles. The H code (65 kA at 440 V) is the high-interrupt variant; an S-code sibling would offer a standard 50 kA at 440 V. No pin-compatible alternative exists outside the same drawout cradle footprint.

What compliance documentation does this brand provide for EVS16H3NW5A?

The breaker is designed to IEC 60947-2 and carries suitability for isolation per that standard. Pollution degree 4 per IEC 60664-1 is specified. Standard Schneider Electric documentation includes a declaration of conformity for CE, plus UL/CSA listings on the family level — confirm the specific listing for your jurisdiction at quote time.

MPN