Schneider Electric EasyPact EVS, EVS25H3NW5A, 3-pole drawout circuit breaker, 2500 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System5A.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS25H3NW5A key specifications
ParameterValue
Control typeElectrically operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS25H3NW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The EVS25H3NW5A is a 3-pole drawout air circuit breaker from the EasyPact EVS range, rated 2500 A at 40 °C and carrying a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The electronic trip unit (EVS Trip System5A) provides overload (long-time), short-time, and instantaneous short-circuit protection, with a thermal memory that holds the thermal model for 20 minutes before and after a trip — so a reclose-and-trip sequence on a hot conductor is accurately timed. Drawout mounting means the breaker chassis stays wired in the switchgear; the moving portion pulls out for inspection or swap without disturbing the bus connections. The IP40 enclosure keeps out tools and fingers but not fine dust — expect this in a clean indoor switchgear lineup, not a washdown area.

Integration notes

Dimensions: 441 mm wide × 439 mm high × 395 mm deep. Rear connection with a 115 mm pitch without spreader. Mounts on a rail base plate. The drawout cradle needs clearance for the racking mechanism — verify the switchgear cubicle depth against the 395 mm plus handle throw. Pollution degree 4 means it's rated for conductive pollution environments (heavy condensation, occasional conductive dust), typical of industrial switchrooms.