Schneider Electric EasyPact EVS, EVS25H3NW5A, 3-pole drawout circuit breaker, 2500 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System5A.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS25H3NW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS25H3NW5A — Electrical ratings
ParameterValue
Rated current (In)2500 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS25H3NW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS25H3NW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS25H3NW5A — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS25H3NW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS25H3NW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The EVS25H3NW5A is a 3-pole drawout air circuit breaker from the EasyPact EVS range, rated 2500 A at 40 °C and carrying a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The electronic trip unit (EVS Trip System5A) provides overload (long-time), short-time, and instantaneous short-circuit protection, with a thermal memory that holds the thermal model for 20 minutes before and after a trip — so a reclose-and-trip sequence on a hot conductor is accurately timed. Drawout mounting means the breaker chassis stays wired in the switchgear; the moving portion pulls out for inspection or swap without disturbing the bus connections. The IP40 enclosure keeps out tools and fingers but not fine dust — expect this in a clean indoor switchgear lineup, not a washdown area.

Integration notes

Dimensions: 441 mm wide × 439 mm high × 395 mm deep. Rear connection with a 115 mm pitch without spreader. Mounts on a rail base plate. The drawout cradle needs clearance for the racking mechanism — verify the switchgear cubicle depth against the 395 mm plus handle throw. Pollution degree 4 means it's rated for conductive pollution environments (heavy condensation, occasional conductive dust), typical of industrial switchrooms.

Frequently asked questions

What is the closest alternative to EVS25H3NW5A in the EasyPact EVS family?

Within the same EasyPact EVS range, the closest sibling is the EVS25H3NW5A itself — there is no pin-for-pin alternative with identical ratings. If you need a different breaking capacity code (e.g., S, N, or L) or a different trip unit, the frame size and drawout footprint remain the same, but the trip unit and breaking capacity change. Check the spec line for your required Icu at the system voltage.

MPN
EVS25H3NW5A