Schneider Electric EVS32H3NW5A

Schneider EVS32H3NW5A EasyPact EVS Circuit Breaker, 3200 A,

MPN EVS32H3NW5A
Active

Schneider Electric EasyPact EVS, EVS32H3NW5A, drawout circuit breaker, 3P, 3200 A at 40 °C, 65 kA Icu at 440 V AC, electronic trip unit, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS32H3NW5A key specifications
ParameterValue
Control typeElectrically operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS32H3NW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The EVS32H3NW5A is a Schneider Electric EasyPact EVS drawout circuit breaker rated 3200 A at 40 °C, with a 65 kA Icu breaking capacity at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2.

The 20-minute thermal memory means the trip unit remembers the thermal state of the breaker after a fault, so reclose-and-trip cycles don't drift. The digital display shows the actual current and the cause of any trip (internal fault, overload, short-circuit), which speeds fault isolation for a field service tech. Pollution degree 4 means it's rated for continuous conductive contamination — think industrial environments with dust, humidity, or mild chemical exposure — not just clean indoor switchgear rooms.

Certified to IEC 60947-2. Suitability for isolation is confirmed per that standard, so it can serve as the service disconnect for the downstream distribution. The contact position indicator gives a visible confirmation of open/closed state.

MPN
EVS32H3NW5A