Schneider Electric EasyPact EVS40H, EVS40H3MW5A, 4000 A drawout circuit breaker, 65 kA Icu at 440 V AC, 3P, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS40H3MW5A key specifications
ParameterValue
Control typeManually operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS40H3MW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS40H3MW5A is a 4000 A drawout circuit breaker from the EasyPact EVS40H series, built for main distribution duty. It carries a 65 kA Icu breaking capacity at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2 — so it handles high-fault utility feeds without cascading upstream. The 3-pole design with an electronic EVS Trip System5A unit gives you overload, instantaneous short-circuit, and short-time short-circuit protection, plus a 20-minute thermal memory that remembers the heat profile before and after a trip. That matters for coordination: it keeps downstream devices from nuisance-tripping on a temporary overload.

The drawout mounting lets you rack the breaker out for safe maintenance without killing power to the bus; the rear connection bolts directly to the bus bars. IP40 keeps tools and fingers out but expects a clean indoor switchroom.

Built to IEC 60947-2 for circuit breakers, with suitability for isolation — so it doubles as a visible-break disconnect when racked out. The utilisation category B means it's designed for selectivity with downstream breakers, not just as a standalone device. Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. That 25 ms maximum breaking time keeps fault energy low enough to protect downstream gear.