Schneider Electric EVS40H3MW5A — Air Circuit Breakers

Schneider Electric EVS40H3MW5A EasyPact EVS40H Circuit Break

MPNEVS40H3MW5A
Active

Schneider Electric EasyPact EVS40H, EVS40H3MW5A, 4000 A drawout circuit breaker, 65 kA Icu at 440 V AC, 3P, electronic trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS40H3MW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS40H3MW5A — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS40H3MW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS40H3MW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS40H3MW5A — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS40H3MW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS40H3MW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS40H3MW5A is a 4000 A drawout circuit breaker from the EasyPact EVS40H series, built for main distribution duty. It carries a 65 kA Icu breaking capacity at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2 — so it handles high-fault utility feeds without cascading upstream. The 3-pole design with an electronic EVS Trip System5A unit gives you overload, instantaneous short-circuit, and short-time short-circuit protection, plus a 20-minute thermal memory that remembers the heat profile before and after a trip. That matters for coordination: it keeps downstream devices from nuisance-tripping on a temporary overload.

The drawout mounting lets you rack the breaker out for safe maintenance without killing power to the bus; the rear connection bolts directly to the bus bars. IP40 keeps tools and fingers out but expects a clean indoor switchroom.

Built to IEC 60947-2 for circuit breakers, with suitability for isolation — so it doubles as a visible-break disconnect when racked out. The utilisation category B means it's designed for selectivity with downstream breakers, not just as a standalone device. Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. That 25 ms maximum breaking time keeps fault energy low enough to protect downstream gear.

Frequently asked questions

How do I get current pricing and availability for EVS40H3MW5A?

Submit an RFQ through this listing. We source this part through independent distribution and confirm availability and current pricing at quote time.

What is the breaking capacity of EVS40H3MW5A?

65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2.

What trip unit does EVS40H3MW5A use?

It uses the electronic EVS Trip System5A, providing overload (long-time), instantaneous short-circuit, and short-time short-circuit protection.

What compliance documentation does Schneider provide for EVS40H3MW5A?

The breaker is certified to IEC 60947-2 and suitable for isolation per that standard. The manufacturer provides a declaration of performance and conformity with the product.

MPN
EVS40H3MW5A