Skip to main content
Schneider Electric EZ9F34206

Schneider Easy9 EZ9F34206 MCB, 6 A, 2P, C-Curve, 4.5 kA

MPN EZ9F34206
Active

Schneider Electric Easy9 series, EZ9F34206 miniature circuit breaker, 2-pole, 6 A rated current, C-curve, 4.5 kA breaking capacity, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZ9F34206 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60898-1
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 4500 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1
Poles2P
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C

All specifications

EZ9F34206 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree2
ColorGrey (RAL 7035)
Depth66.5 mm
Width36 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric Easy9 EZ9F34206 is a 2-pole miniature circuit breaker rated 6 A with a C-curve trip characteristic (magnetic trip between 5 and 10 times In). The 4.5 kA breaking capacity at 230/400 V AC per IEC 60898-1 means it safely interrupts a fault current up to that level without welding contacts or cascading upstream — adequate for most residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit. For motor circuits or transformers with higher inrush, a D-curve would be preferred; for purely resistive loads, a B-curve could be used. This part is sized for a 6 A final subcircuit.

The 36 mm width occupies 4 module pitches at 9 mm each — standard for a 2-pole MCB in a distribution board. Tunnel-type terminals accept 1–25 mm² rigid or 1–16 mm² flexible cable; tighten to 2 N·m. IP20 finger-safe terminals suit enclosed panel use.

MPN
EZ9F34206