Schneider Electric EZC100H1100

Schneider EasyPact EZC100H1100 1P 100A MCCB, 25kA at 240V

MPN EZC100H1100
Active

Schneider Electric EasyPact EZC100H, 1-pole 100 A thermal-magnetic MCCB, TM-D trip unit, 25 kA Icu at 240 V AC, 10 kA Icu at 125 V DC, fixed mount, toggle control.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H1100 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100H1100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It's 25 mm wide — one pole wide — so it slots into a backplate-mounted assembly without eating up rail space. The 25 kA Icu at 240 V AC means it'll clear a substantial fault on a 240 V distribution bus without upstream coordination headaches; at 415 V AC it's 5 kA Icu, so watch the system SCCR if you're using it on a 400 V line. It's a Category A breaker — no intentional short-time delay, so it's meant for instant trip on fault, not selective coordination with downstream devices.

The breaking capacity code 'H' tells you this is the high-interrupting version of the EZC100 frame. At 125 V DC it's 10 kA Icu, which covers battery-bank and UPS output breakers in telecom/DC plant applications. The IP20 finger-safe terminals and IK07 impact resistance handle the usual enclosure-installation abuse. Mechanical durability of 13,000 cycles — that's the expected life of the mechanism under no-load switching. For a distribution breaker that cycles a few times a year in normal service, that's effectively a lifetime. If you're switching it daily as a disconnect, you'll want to check the electrical endurance curve (not in this spec set) for the actual load current.

Mounting & connections

Fixed mount on a backplate — no DIN rail adapter on this one. The 25 mm pole pitch matches standard panelboard busbar spacing. Front connections both top and bottom, so busbar runs and load cables land on the same face. Connection pitch is 25 mm, which aligns with standard distribution lug kits. Toggle control with positive contact indication — you can see the contact position through the front window, not just the handle position. That matters for lockout/tagout verification.