Schneider Electric EasyPact EZC100H, EZC100H2016, 2-pole circuit breaker, 16 A rated current, TM-D thermal-magnetic trip unit, 10 kA Icu at 125 V DC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H2016 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100H2016 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width50 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Breaking capacity is the key selection figure here. At 125 V DC single-pole it clears 10 kA Icu per IEC 60947-2; at 250 V DC 2-pole it also clears 10 kA. On AC, the 380…400 V 50/60 Hz rating is 30 kA Icu, and at 220…240 V it reaches 50 kA Icu. The unit is front-connected top and bottom, mounts fixed to a backplate, and uses a toggle for manual control. Positive contact indication gives a visual confirmation of the contact position independent of the toggle mechanism — useful during panel commissioning when you need to verify isolation without assuming the handle position.

Dimensions are 130 mm high, 50 mm wide, 60 mm deep. The 2-pole configuration protects both poles (2t) with no neutral protection. If your circuit requires a switched neutral or a 4-pole break, this is not the variant. For a straightforward 2-wire distribution feed — single-phase or DC — it fits without extra wiring complexity.

The breaker is certified to JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2, and EN/IEC 60947-1. Rated insulation voltage is 690 V AC, operational voltage is 550 V AC or 250 V DC — the DC rating covers common 125 V and 250 V battery or rectifier circuits. The 16 A rating at 40 °C is the standard reference; at 50 °C the trip unit still carries 16 A, so no derating is needed up to that temperature for the trip unit itself — though the overall breaker rating at 40 °C is the one to use for NEC or IEC cable sizing.