Schneider Electric EZC100H2040

Schneider EasyPact EZC100H2040 40A 2P MCCB, 10-100kA IC

MPN EZC100H2040
Active

Schneider Electric EasyPact EZC100H, EZC100H2040, 2-pole MCCB, 40 A rated current, TM-D thermal-magnetic trip, 10–100 kA breaking capacity, IP20.

$52.89 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H2040 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100H2040 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width50 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100H2040 is a 2-pole EasyPact EZC100H moulded-case circuit breaker rated 40 A at 40 °C, with a TM-D thermal-magnetic trip unit. The 40 A trip rating at 50 °C means the breaker holds full load without nuisance tripping in a warm panel — the TM-D curve handles motor inrush and distribution loads. Breaking capacity varies by voltage: 100 kA Icu at 110–130 V AC, 50 kA at 220–240 V AC, 30 kA at 380–415 V AC, 20 kA at 440 V AC, and 10 kA at 550 V AC 50/60 Hz, all per IEC 60947-2. On DC, it delivers 10 kA Icu at 125 V DC (1-pole) and 250 V DC (2-pole). The H breaking-capacity code means this is the high-interrupting version of the EZC100 frame — sized for distribution panels where fault currents can hit 100 kA on low-voltage AC. IP20 finger-safe terminals and IK07 impact resistance cover handling during installation.

Deployment context

Fixed backplate mounting with front-facing connections — upside and downside both front-connect, so it panels into a distribution board or enclosure with a 25 mm connection pitch. The 2-pole format (2t protected poles, no neutral protection) suits single-phase or DC branch circuits where only the line and switched neutral need protection. Mechanical durability of 13,000 cycles fits distribution duty (not frequent switching like a contactor).

MPN
EZC100H2040