Skip to main content
Schneider Electric EZC100H4080

Easypact EZC100H4080 MCCB, 80 A, 100 kA Icu at 240 V

MPN EZC100H4080
Active

Schneider Electric EasyPact EZC100H, EZC100H4080, 4-pole fixed MCCB, 80 A thermal-magnetic TM-D trip, 100 kA Icu at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H4080 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100H4080 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width100 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Breaking capacity — the number that decides the fit

The EZC100H4080 carries a 100 kA Icu at 110–130 V AC and 50 kA at 220–240 V AC — meaning it can safely interrupt a fault current up to that level without welding or bursting the contacts. At 380–400 V it still holds 30 kA, and at 550 V AC it holds 10 kA. On DC sides, it is rated 10 kA at 125 V DC (1-pole) and 250 V DC (2-pole). That covers most industrial distribution panels fed by a transformer or a generator step-down.

The TM-D trip unit is thermal-magnetic — thermal for overload (inverse-time, responding to RMS heating), magnetic for short-circuit (instantaneous pick-up). The breaker is Category A (no intentional short-time delay), meaning it trips fast on a hard fault — standard for a distribution feeder or branch panel where selectivity is handled upstream with a time-delay breaker or fuse.

Fixed-mount on a backplate, front-connected both line and load. The 4-pole body is 100 mm wide, 130 mm tall, 60 mm deep — a compact footprint for a 100 kA-rated 4-pole. Connection pitch is 25 mm, which matches standard busbar spacing. IP20 finger-safe terminals are standard; the enclosure must provide the rest of the ingress protection. IK07 impact rating means it survives a 2 J hammer blow — enough for panel-door mounting if the door is not exposed to heavy tools.

The EZC100H4080 is listed as current production (active lifecycle). It is certified to EN/IEC 60947-1 and -2, JIS C8201-2-2, and GB/T 14048.2 — so it is accepted in European, Japanese, and Chinese markets.

MPN
EZC100H4080