Skip to main content
Schneider Electric EZC100N1100

Schneider Electric EZC100N1100 EasyPact EZC100N, 100 A, 1-Po

MPN EZC100N1100
Active

Schneider Electric EasyPact EZC100N, MCCB, 1 pole, 100 A, thermal-magnetic TM-D trip unit, breaking capacity 25 kA at 110-130 V AC, front connections, IP20, backplate mount.

$39.96 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100N1100 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100N1100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC100N1100 is a 1-pole EasyPact EZC100N moulded-case circuit breaker rated 100 A at 40 °C (trip unit rating 100 A at 50 °C) with a thermal-magnetic TM-D trip unit. It provides short-circuit and overload protection in distribution panels. The breaking capacity varies by voltage: 25 kA Icu at 110–130 V AC, 18 kA at 220–240 V AC, and 2.5 kA at 400–415 V AC — so at 400 V line-to-line the fault-interrupt rating drops sharply; selectivity studies need the 2.5 kA figure, not the 25 kA headline. Rated operational voltage covers 125 V DC (1-pole) and 415 V AC 50/60 Hz; insulation voltage is 690 V AC.

IP20 finger protection on the front face; IK07 impact resistance means it withstands a 2 J hammer blow — adequate for panel-door mounting where accidental tool strikes occur.

MPN
EZC100N1100