Skip to main content
Schneider Electric EZC100N3032

Schneider EasyPact EZC100N3032 32A MCCB, 10kA at 440V

MPN EZC100N3032
Active

Schneider Electric EasyPact EZC100N series, EZC100N3032, 3-pole molded case circuit breaker, 32 A rated current, thermal-magnetic TM-D trip unit, 10 kA Icu at 440 V AC.

$49.96 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100N3032 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100N3032 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width75 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

This is a distribution-grade MCCB from the EasyPact EZC100N family, built for fixed backplate mounting with front-front connections. The 32 A rating at 50 °C means it carries full current in a warm panel without derating — relevant when the breaker shares an enclosure with other heat sources. Breaking capacity follows the voltage: 10 kA Icu at 440 V AC, 18 kA at 380–400 V, 25 kA at 220–240 V, and 5 kA at 550 V AC or 250 V DC (2P). The DC ratings (5 kA at 125 V DC 1P, 5 kA at 250 V DC 2P) cover control-circuit and battery-string protection, though this is primarily an AC distribution breaker.

The 32 A TM-D trip unit provides overload and short-circuit protection. Dimensions: 75 mm wide, 130 mm high, 60 mm deep. The 25 mm connection pitch is standard for this frame size; front-front connections simplify panel layout and busbar routing.

It also meets JIS C8201-2-2 and GB/T 14048.2, covering Japanese and Chinese installation codes respectively.

MPN