Skip to main content
Schneider Electric EZC100N3032 — Circuit Breaker Accessories

Schneider EasyPact EZC100N3032 32A MCCB, 10kA at 440V

MPNEZC100N3032
Active

Schneider Electric EasyPact EZC100N series, EZC100N3032, 3-pole molded case circuit breaker, 32 A rated current, thermal-magnetic TM-D trip unit, 10 kA Icu at 440 V AC.

$49.96Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100N3032 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100N3032 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]32 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100N3032 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating32 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100N3032 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100N3032 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100N3032 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2

Product details

This is a distribution-grade MCCB from the EasyPact EZC100N family, built for fixed backplate mounting with front-front connections. The 32 A rating at 50 °C means it carries full current in a warm panel without derating — relevant when the breaker shares an enclosure with other heat sources. Breaking capacity follows the voltage: 10 kA Icu at 440 V AC, 18 kA at 380–400 V, 25 kA at 220–240 V, and 5 kA at 550 V AC or 250 V DC (2P). The DC ratings (5 kA at 125 V DC 1P, 5 kA at 250 V DC 2P) cover control-circuit and battery-string protection, though this is primarily an AC distribution breaker.

The 32 A TM-D trip unit provides overload and short-circuit protection. Dimensions: 75 mm wide, 130 mm high, 60 mm deep. The 25 mm connection pitch is standard for this frame size; front-front connections simplify panel layout and busbar routing.

It also meets JIS C8201-2-2 and GB/T 14048.2, covering Japanese and Chinese installation codes respectively.

Frequently asked questions

What is the breaking capacity of the EZC100N3032 at 440 V?

10 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–400 V it rises to 18 kA, and at 220–240 V to 25 kA. For DC applications, it is rated 5 kA at 125 V DC (1P) and 5 kA at 250 V DC (2P).

MPN
EZC100N3032