Schneider Electric EasyPact EZC250H, circuit breaker, 3P, 175 A, thermal-magnetic TM-D trip unit, 36 kA Icu at 400 V AC, IP20, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250H3175 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC250H3175 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC250H3175 is an EasyPact EZC250H circuit breaker — a 3-pole, 175 A thermal-magnetic unit with a TM-D trip block, built for distribution duty in fixed-mount backplate panels. It carries a 36 kA Icu at 400 V AC (IEC 60947-2) and a 25 kA Icu at 440 V AC, so it clears faults up to that level without cascading upstream. IP20 finger-safe terminals and IK07 impact resistance suit it for enclosed switchboards where incidental contact is the only exposure.

The H breaking-capacity code means this breaker handles 36 kA Icu at 380–415 V AC (the common 400 V class) and 85 kA Icu at 220–240 V AC. On DC circuits it manages 30 kA Icu at 125 V DC (1P) or 250 V DC (2P). These numbers govern coordination with downstream devices — the high Icu at 240 V AC lets it serve as a main breaker in a split-bus panel where the utility fault current is high, while the 10 kA Icu at 550 V AC covers 480 V delta feeds.

Integration notes

Fixed-mount backplate installation — no DIN-rail adapter. Dimensions: 165 mm height, 105 mm width, 60 mm depth. The toggle handle provides positive contact indication, so at a glance you see whether the contacts are open or closed.

MPN