Schneider Electric EZC250H3250

Schneider Electric EZC250H3250 EasyPact EZC250H Circuit Brea

MPN EZC250H3250
Active

Schneider Electric EasyPact EZC250H, EZC250H3250, 3P circuit breaker, 250 A, thermal-magnetic TM-D trip unit, 10-85 kA breaking capacity, 60 mm depth, 105 mm width, 165 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250H3250 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC250H3250 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC250H3250 is a 3-pole EasyPact EZC250H circuit breaker from Schneider Electric, rated 250 A at 40 °C ambient with a thermal-magnetic TM-D trip unit. The 250 A trip rating at 50 °C means the breaker holds full rated current in a warm panel — useful when the enclosure is stacked with other heat-generating devices. The breaking capacity varies by voltage: 85 kA Icu at 240 V AC, 36 kA at 400 V AC, and 10 kA at 550 V AC. At 400 V, that 36 kA Icu is typical for a distribution board downstream of a transformer; the 10 kA at 550 V covers industrial line-to-line supplies where fault current is lower. The 690 V rated insulation voltage and 550 V AC / 250 V DC operational voltage confirm it handles standard three-phase 480 V and 600 V class systems, plus DC circuits for battery or UPS tie-ins. The 3t protected poles with no neutral protection means it's a straight three-pole breaker for a three-phase load — no switched neutral.

Deployment context

Fixed mounting on a backplate with front connections top and bottom — this breaker bolts into a panel, not onto a DIN rail. The toggle control gives positive contact indication so an operator can visually confirm the breaker is open or closed without metering.

Designed to EN/IEC 60947-2 and GB/T 14048.2 — the global standard for low-voltage molded-case circuit breakers. IK07 impact resistance handles light tool drops during panel assembly. Mechanical durability of 10,000 cycles is typical for a distribution breaker — not for frequent switching, but fine for protection duty where it operates a few times a year.

MPN
EZC250H3250