Schneider Electric EZC250H3250 — Circuit Breaker Accessories

Schneider Electric EZC250H3250 EasyPact EZC250H Circuit Brea

MPNEZC250H3250
Active

Schneider Electric EasyPact EZC250H, EZC250H3250, 3P circuit breaker, 250 A, thermal-magnetic TM-D trip unit, 10-85 kA breaking capacity, 60 mm depth, 105 mm width, 165 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250H3250 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H3250 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]250 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250H3250 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating250 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H3250 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250H3250 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H3250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2

Product details

The EZC250H3250 is a 3-pole EasyPact EZC250H circuit breaker from Schneider Electric, rated 250 A at 40 °C ambient with a thermal-magnetic TM-D trip unit. The 250 A trip rating at 50 °C means the breaker holds full rated current in a warm panel — useful when the enclosure is stacked with other heat-generating devices. The breaking capacity varies by voltage: 85 kA Icu at 240 V AC, 36 kA at 400 V AC, and 10 kA at 550 V AC. At 400 V, that 36 kA Icu is typical for a distribution board downstream of a transformer; the 10 kA at 550 V covers industrial line-to-line supplies where fault current is lower. The 690 V rated insulation voltage and 550 V AC / 250 V DC operational voltage confirm it handles standard three-phase 480 V and 600 V class systems, plus DC circuits for battery or UPS tie-ins. The 3t protected poles with no neutral protection means it's a straight three-pole breaker for a three-phase load — no switched neutral.

Deployment context

Fixed mounting on a backplate with front connections top and bottom — this breaker bolts into a panel, not onto a DIN rail. The toggle control gives positive contact indication so an operator can visually confirm the breaker is open or closed without metering.

Designed to EN/IEC 60947-2 and GB/T 14048.2 — the global standard for low-voltage molded-case circuit breakers. IK07 impact resistance handles light tool drops during panel assembly. Mechanical durability of 10,000 cycles is typical for a distribution breaker — not for frequent switching, but fine for protection duty where it operates a few times a year.

Frequently asked questions

How do I get current pricing and availability for EZC250H3250?

The EZC250H3250 is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current pricing and availability at the time of your order.

What is the breaking capacity of EZC250H3250 at 400 V?

At 400...415 V AC 50/60 Hz, the EZC250H3250 delivers 36 kA Icu per IEC 60947-2. This is sufficient for most distribution boards downstream of a transformer with typical fault levels.

What compliance documentation does this brand provide for EZC250H3250?

The EZC250H3250 is designed to EN/IEC 60947-2 and GB/T 14048.2 standards. It carries IP20 finger protection and IK07 impact resistance. The manufacturer typically provides a declaration of conformity and test reports upon request through the supply channel.

MPN
EZC250H3250