Skip to main content
Schneider Electric EZC400H3350

Schneider Electric EZC400H3350 EasyPact EZC400H MCCB, 400 A,

MPN EZC400H3350
Active

Schneider Electric EasyPact EZC400H series, EZC400H3350, molded case circuit breaker, 3-pole, 400 A rated current, 50 kA Icu breaking capacity, TM-D thermal-magnetic trip unit, fixed mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC400H3350 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch44 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC400H3350 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width140 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC400H3350 is a 3-pole EasyPact EZC400H molded case circuit breaker rated 400 A at 40 °C (In) with a TM-D thermal-magnetic trip unit. The TM-D trip unit provides both overload (thermal) and short-circuit (magnetic) protection in one package, with a magnetic trip threshold of 3200 A. Mounts fixed to a backplate (not DIN rail), so plan for a dedicated mounting surface in the enclosure. Front-connect terminals on both line and load sides simplify bus-bar or cable routing in a standard distribution panel layout.

Compliance documentation is available: the breaker carries IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2 approvals, plus IP20 and IK07 mechanical impact protection.

Integration notes

Dimensions: 255 mm high, 140 mm wide, 140 mm deep. The 44 mm pole pitch matches standard bus-bar spacing for 3-pole breakers in this class. Mechanical durability is 10,000 cycles; electrical durability is 4,000 cycles at 415 V AC. That's typical for a distribution breaker — not intended for frequent switching duty like a contactor, but fine for isolation and backup protection in a fixed installation.