EZC400H4400 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC400H4400 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width185 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC400H4400 is a 400 A thermal-magnetic MCCB from the EasyPact EZC400H series, built for distribution duty in fixed-mount switchboards. The trip unit is rated 400 A at 50 °C — that's the continuous current it carries without tripping at that ambient, so in a 40 °C panel it handles the same 400 A with extra thermal headroom. The TM-D trip combines a thermal bimetal for overload protection and a fixed magnetic trip set at 4000 A for short-circuit protection. At 220-240 V AC it rises to 70 kA Icu. The 'H' in the name designates this high-breaking-capacity version, which gives selectivity headroom downstream of a larger upstream device. The 4-pole version (4P) switches all three phases plus the neutral, though the neutral pole is unprotected — it tracks the phase poles mechanically.